The recent patches for the PCI-7344 card helped our speed problem but not this one. Re: PCI7344 and Copley Accelus Drive. The VIs send motion commands to the board and also monitor the position of the axis. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. If you select the Firmware tab, there should be a button near the top of the screen callled "Update Firmware" If the firmware is up to date, it will be grayed out. 3008 to 7. Is there a way to reduce this time delay?I am trying to operate NI Motion with a PCI-7344 card inside LabView 64-bit on a WIN7/64 platform. Axis 1) In the Axis Configuration tab, set Type to Stepper. Best regards, Jochen Klier. Don't want to physically move the motor to zero out the encoder. It is related to 3D printer. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. NI-DAQmx. If you are using LabVIEW, there are many example programs that ship with the NI-Motion driver. 02 seconds. 配置您的步进器设置. You won't be able to achieve these types of signals with a 7344 motion control board. Is there a way to synchronize motion data (PCI-7344) with AI data? I was hoping that I could capture the position by RTSI to a spare AI channel, but it appears that the position capture functions store the data internally. I've got a PCI card (PCI 7344 for motion control). I use Windows NT4 and Labview 6. 25 ms corresponding to 0 degrees, 1. I am using axis 3 with encoder 1 as the primary feedback, and as the control output. Figure 7. 1 (NIMotion7. I have a very strange problem. Because I have two motion control systems (PC with 7344 and MID7654 controlling 3 axis servo system) I decided it was best to . National Instruments PCI-7344. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. 08-10-2007 01:26 AM. All of 3 motors require +5V 24mA for the Mike encoder. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. Re: LabVIEWアップデートに伴うPCI-7344のエラー. Regards, Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). Problem 2 The position does not automatically reset to zero when the z. A NI PCI-6527 48-bit digital I/O board that resides in another PCI slot inside the PCWhen I transferred my PCI-7344 motion controller board to another PC, it is recognized "PXI4200"in MAX. 2. am rules/80-net-setup-link. The 7344 can do a frequency of 40 Hz or 78 Hz (which either. What would it take to build. I am using LabVIEW 2014 and NI PCI 7344(motion controller). I've never used LabVIEW 6. The cards do not work on a Computer with differen Hardware, nor when the operating system is Windows XP. Due to synchronization constraints I need hardware scanning synchronized with some internal clock instead of software scanning using a set. flx and Read Trajectory Data. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. PLEASE, i appriciate any help, because its not working. I set up the axis using MAX. I would also appreciate one for the Video Capture Board PCI-1409. 12 PCI 7344 MAX -Two-axis Configurations 39 3. The 7342 follows this position profile using a spline algorithm. Current PC config is: Pentium 4 - 2. I'm using the PCI-7344/UMI-7764 to control the motors. 20. I have one 3 axes(X,Y,Z) mchine. I would appreciate if you can suggest me any research that I could do on this system which involve 3 axes motion -using all ac servo motor (automated storage and retrieval system) - I. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. org Mon Sep 8 22:44:35 PDT 2014. It is connected to a UMI-7764 breakout box. Aerospace, Defense. 17) before running VI. You willI have a E-Stop button on my machine. 3003 to 7. Axis 1 is working fine, i can control perfectly the motor, I. we are using PCI 7344 and labview 7. 579 views 3 years ago. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. Now their is a connector on the Motion control card for Digital I/O. Using MAX to test the. Shut down your computer. The parameters of that algorithm can be modified, but the algorithm itself is fixed. This controller is able to achieve simultaneous three-axis motion trajectories through linear, spherical, circular or helical interpolation, which will placate all our requirements for concurrent three-axis machining and also for the FDM operation. Options. 10-02-2007 06:58 AM. comHi,All I use NI PCI-7344,UMI-7764 and servo motor in my project. PCI-7344 cua NI Corp se tch hp hai bo ieu khien servo va step motor. Using the X-Y Grid Inspection (Template). In my VI, I have called the Enable Limits. I have been using a PCI-7344 (driven by NI Motion 5. 0 and NI-Motion 7. Fast Quotes & Shipping. Options. Hello, I'm using MAX to disabling Axis, Axis2, Axis3 of PCI-7344 and UMI7774, I click save and "initilize" in MAX, i get message "OK". . The PCI‑7344 also provides contouring capability for complex moves. I have tried, but the outcome always changes the sharp corners into round corners with excessive r values. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Issue Details. activate the INH output via software. I have updated all of our drivers etc and the card initializes fine. ConventionsCan I use two NI - PCI 7344 motion controllers in one PC. 14 PC-Based System with FP 2000 Hardware Configurations 42. the drive feeds back a simulated. . From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. It looks like the umi-7774 connected to the motor drive only with 2 pins from the Control connector (pin#1 and pin#9) and the Encoder of the servo connected to few pins in the Feedback connector and thats it. Applications Engineering Group. comPXI-7344. com FREE DELIVERY possible on eligible purchasesI'm using a PCI-7344 with an MD7506 motor driver from RS. Buy PCI-7344: Graphics Cards - Amazon. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. . MAX 5. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. It is controlled by a host computer with a PCI-7344 motion controller card from National Instrument. Worldwide Technical Support and Product Information National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100The PCI-7344, PXI-7344, PCI-7334, and PXI-7334 controllers are fully compatible with the PCI Local Bus Specification, Revision 2. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. It works fine in the LabVIEW environment but ignores does not perform any action that uses the motion card. Save on shipping. cmd_data This an array of six integers used to send parameters and receive values associated with the execution of the specified command. Hello, I am using a PCI-7344 motion controller card to drive 2 stepper motors in closed loop mode. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. The marking triggering signal (TTL) generated by a rotary encoder is applied to the trigger input of the NI-MID 7604 module trough a delay circuit (2) and a logic gate (AND) of SPUC. But the MAX couldn't read the current traject. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. The 7342 follows this position profile using a spline algorithm. command This is one of the commands described below. I am a Master’s student of International Islamic University Malaysia. On 2 different systems and 2 different motion control cards (pci-7334 and 7344) after running the cards for approximately 30 minutes I get errorThe PCi 7344 can control a brushless servo provided that the drove for your motor can take a +/- 10 volt torque signal or a step and direction signal as a command signal. NI 7330 NI 7332, NI 7334. Unless otherwise noted, text applies to all controllers in the 7344 family. Re: a problem with Flex-6C controller MarcoPolo5. Options. Not all NI Motion controllers can control a step motor, but the following can: PCI-7332, PXI-7332, PCI-7334, PXI-7334, PCI-7342, PXI-7342, PCI-7344, PXI-7344, PCI-7352, PXI-7352, PCI-7354, PXI-7354, PCI-7356, PXI-7356, PCI-7358, PXI-7358, and PCI-7390. 05-10-2006 05:05 PM. PCI-7344 PCL812PG TRỤC CHÍNH BÀN MÁY CHI TIẾT LỰC KẾ Hình 1. Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. Dennis_Knutson. Current PC config is: Pentium 4 - 2. I have neither asked for nor received a calibration certificate for a PCI-7344. 0. FlexMotion 5. The Problem is feedback from each axis (AZ & EL). . When i am using PCI Flex-6C,Finding home functions does not work as the PCI 7344 do, The controller stops axis 1 and axis 2 during the finding home sequences when the axis 3 encountered home switch first. 4-Axis, Stepper PXI Motion Controller Module. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 1. (The servo drive manual is here:The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Go to the Axis Configuration option, under the desired axis (e. If you have non-plug and play (ISA bus) boards, refer to the ISA Installation (PC-FlexMotion-6C Only) section of this document. Mark as New; Bookmark. I have a software controlling 4 servo motors using PCI 7344,UMI7764 and NI-motion 14. I connect the pins of the control connector of the UMI-7774 (Axis 1) as i describe in the image i attach. Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. Its very easy to configure using MAX and also easily programmable using the simple to understand VIs provided by NI. The analog signal can be from -10 to 10V. This motion controller can control upto 4 servo motors and can give 2 PWM. 6: Cấu trúc của máy phay CNC. it is going to be sqaure wave signal . I'm trying to run a device that someone assembled before but the . The DISABLED LED of the Axis1 - Axis4 on the e UMI is not Lit, i also notice that in MAX under Motion IO setting, the "inhibit input setting" is grayed. . My pr. I. 75 ms. はじめまして。投稿させていただきます。 現在、PCI-7344とUMI-7764を用いて3つのACサーボモータを速度制御しようと考えています。 用いるサーボモータとアンプはそれぞれ、三菱電機製のHC-KFS13と、MR-J2S20A1です。 初歩的な質問をして申し訳ないのですが、アンプとUMI-7764の結線の方法がわかりませ. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. I have no choice in using synchro's as feedback. lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. 0 and earlier. The trigger frequency should be very high (> 4 kHz). After un-installing all NI software I now find that I cannot get the system to recognize the PCI-7344 board. I am seeing the PWM waveform on CRO. Single-board rio oem devices (50 pages) The PCI-7344 is not a working device but something I created to explore the change board ID option. Refer to the Glossary section of this manual for definitions of selected related terms. The fact is ,as most say,the driver is not suitable under non-windows systems. in another word it will show me the STL file is being created layer by layer. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. 10-02-2007 06:58 AM. . option from the right-click menu. Configure your stepper settings. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. g. . Best regards, Jochen Klier. 5f1. Now i am using a PCI-7344 motion controller to control my nanomotion stage. The step/ direction signals from the controller card are converted to phase-drive signals using three UCN5804B stepper ICs, one for each axis, and routed through a 25-pin D-subminiature connector cable to the MAXNC-10. Provides support for NI data acquisition and signal conditioning devices. 2的强大功能,我们得以 在短时间内完成了控制系统的开发,同 时保证了机械臂的运动精度与负载能 力。The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Hi, I am running a motor using the PCI 7344 motion control board and a MID-7654 servo with encoder feedback. There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Res. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Servo motors expect a pulse every . Hello, I really really need help in this: I have UMI 7774 and PCI 7344 and i have problems to Connect it to my Servo Motor Drive. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The pulse should last from 1. 02 seconds. I have verified the connection is working. Cary, NC,. 25 ms to 1. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. PCI 7344 card. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. I am using a PCI-7344 motion control card with a UMI-7764 break out box. I have tried all the Settings discussed in the Forums and they still don't run. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. flx, but i don't know how to wire it. It offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high. How do I do that? Hopefully, there is also a way for me to h. 付属されていた新しいドライバCDはインストールしましたでしょうか?. 0. In order to make the encoder work again, I need to do a complete shutdown. hwdb Marcel Holtmann holtmann at kemper. 1. An introduction to the National Instruments PCI-7344 Motion ControllerFeatured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID. NI 7350 NI 7352, NI 7354, NI 7356, NI 7358. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. Hello, we are running our lab setup on WIN7 and soon we have to switch to WIN10. 08-10-2007 01:26 AM. Manufacturer: National Instruments. Send. MAX 5. Options. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. Thanks. So the servo's torque reaches the target, it shoud be stopped at that postion unless any change in servo's torque happens. Refer to the Glossary section of this manual for definitions of selected related terms. You won't be able to achieve these types of signals with a 7344 motion control board. There was a "broken" device PCI-7344 under NI Motion Devices, which status said something like "This device has been removed or could not be detected" and the Reset command said something. Please. Dennis_Knutson. It is very likely that you will not be able to simulate the FW-7344 controller in MAX, due to these limitations. . Re: Position Control of compumotor linear servo table and GV-U6E with PCI-7344. The PCI 7340 (4 axis) board is a drop in replacement for the PCI-7344. controller in the 7344 family and contains information concerning their operation and programming. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. . Regards Sudhir Sawant Emai. National Instruments FW-7344. We have successfully done several projects using the Parker-Compumotor Gemini GV servo drive and the NI-7344 and the NI UMI-7764 breakout box. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. 0. 2. I am using NI PCI-7344 motion controller card with NI MID-7604 stepper motor driver. 2: I wrote an onboard program that makes a 2axis move and one/two onboard program(s) that write with HighSpeedCapture the Positions to a buffer. It is related to 3D printer. The system works ok, except I have no control over the velocity (does not respond to the vel input vi) as well as there is some hysteresis in the system that provides a large deadband area in the operation about the point where the. C74B552B@univ-valenciennes. PCI-7344 was listed as an obsolete card already. pci-7340 initialization problem. While this is happening, I need to change the velocity of one of the motors. Lực cắt tham chiếu CNC FANUC Máy tính 2 + Phần mềm hiển thi (DASYLab)+ Điều khiển thích nghi Q trình phay Lượng chạy dao Card điều khiển Flexmotion PCI - 7344 Máy tính 1 + CNC Controller Card PCL -812PG Điều chỉnh lượng chạy dao Luợng chạy dao Lực kế Hình 1. The contour trajectory can only be updated every 10 ms, so it is too slow for my application. PCI-7344 P70350 drive NI 3 stack Nema 23 Motor P7000 tools used to set the drive steps/revolution to 5000 (microstepping) in MAX and LabVIEW Steps/rev are loaded as 5000 Encoder is resolution is 1000 (so 4000 counts per revolution - verified by killing axis and rotating by hand. . 1 . . Lai Wechat:17750010683 Whats app:+86 17750010683Hello, I am fairly new to LabVIEW and was wondering how to implement incremental rotary encoders into a motion control VI. Unfortunately the output pulse has a length of about 20 ms and so I have to decrease the speed of my stage rapidly (otherwise the. I am not creating an installer for the program and I am trying to run it on the same machine that has the development environment. 客户使用pci-7344,umi-7764连接第三方的电机和驱动器,搭建了一个闭环控制系统,但发觉电机编码器反馈回的值有些问题. 2 version but I can't be initialize the motion card in MAXDiscontinued NI motion products (PCI/PXI-7334) Affected model numbers include: PCI-7332; PCI-7334; PCI-7342; PCI-7344; PCI-7352; PCI-7354; PCI-7356; PCI-7358Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. Dear Engineers, Now we are useing PCI7344 on motor-controlling. ) angle. These devices run the PID loop onboard in realtime and you only need to set parameters like travel distance, speed and acceleration. 20. Hi, I'm using PCI-7344 & UMI 7764 to control dc motor on servo mode, but i have a question, when i define contouring points that value was smallerHi, i have PCI-7344 and UMI-7774 that i want to connect to this Servo motor drive of Yaskawa. The 7334 controllersHello. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. I've been using NI, PCI-7344 motion controller. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. I have just completed the cable that connects the amplifier to the encoder. Initialize your controller. 能否用NI运动控制卡读取非正交编码器? 硬件: Motion Control>>Controllers>>PCI-7344, Motion Control>>Controllers>>PXI-7344, Motion Control. If you need a specific firmware or series relating to PCI-7344, we probably have it. Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For further support. In my program, the 1st step is to run "Clear Power Up Status. Remote Printing. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Page 1 PXI-7344. Page 1 PCI-7334. All Manuals. This controller is designed for PXI, PCI, and 1394 bus computers. 1. We are using 4 axis of the PCI-7344 in open loop stepper mode. 2をインストールするまでは全く問題なく動作していましたが、Motion Assistant 1. Re: problems with a PCI-7344 motion controller. I would like know if PCI-7344 Stepper/Servo Motion Controller performs electronic camming. The Motion driver with the PCI 7344 has its own algorithm in place. We have just recently switched to a new hardware revision and now all boards don't show up with their specific names but with the name of the board family: Board Family Specific Boards. A declassification procedure for each of these boards would also meet my requirements. I know it executes electronic gearing but I need itDear Mr Scott R, NI Application Engineer, You already answered my question on the impossibility of implement fuzzy logic control on PCI 7344 card. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. . National Instruments PXI-7344, 777935-01. 8 degree pitch (200 steps per rev). The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. The fact is ,as most say,the driver is not suitable under non-windows systems. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. National Instruments PCI-7344 4-Axis Stepper/Servo Controller Card This unit ships sealed in the manufacturer's static bag. Featured with advanced motion control, handy software tools, and motion VI libraries (to be used with LabVIEW), the NI PXI-7344 (Part Number: 777935-01) is a 4-Axis, PXI Stepper/Servo Motion Control Module. If yes, then how to configure the other one, so. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. Since, I'm waiting in a loop for the Move Complete bit, the program (VB 6. NI 7340 NI 7342, NI 7344. I met a problem in using the Labview and it is extremely urgent (I have to make it work in 24hrs). Motion Control 7344 Hardware User Manual 7344 Hardware User Manual July 1999 Edition Part Number 322504A-01. 8. 01-30-2006 10:29 AM. This warranty includes parts and labor. 04-26-2021 10:40 AM. The onboard CPU uses an embedded real-time OS. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. I am using PCI-7344 control card with MID-7654 amplifier driving a three axis dc motor servo system. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Actually i want use 2 analog input and create the sample hold vi. The 7344/7334 controllers are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. Using PCI-7344 and MID-7604 and FLEXMOTION. It is related to 3D printer. Downloadable Technical Manuals and Datasheets. Pxi-7344 provides hybrid motion trajectory control and fully coordinated circular, linear, point-to-point, gear and vector. The PC runs on Windows XP、NI-Motion 6. 0. Solution Accepted by topic author domarm Re: Compatibility of PCI-7344 on WIN10 TSE_Expert NI Employee (retired) 06-13-2019 03:04 AM Options Hi Martin, yes it. Looking to measure speeds up to 500 RPM. Use a higher resolution encoder. Please let me know if you have any additional questions on this issue. We have a drive which sometimes needs manual adjustment, so we have to turn off the torque, i. Any combination of 0 to 4 open loop or closed loop stepper motors and 0 to 4 servo motors (always closed loop) is allowed. 4-Axis, Stepper/Servo PXI Motion Controller Module—The PXI‑7344 is recommended for both simple and complex motion applications. Ca hai ho tr ay u viec lap trnh ieu khien chuyen ong cho phep ieu khien toi a 4 truc ong thi va oc lap. Because of the reason mentionned in the link in my first mail, I doubt that a calibration certificate exists for this card. Hardware Using the existing Rhino Robotics Ltd. . If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. The PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. Options. PCI-7344 Servo Products from NATIONAL INSTRUMENTS 2-Year Warranty, Radwell Repairs - DISCONTINUED BY MANUFACTURER, MOTION. 0 and NI-Motion 7. I need to be able to read the RPM of an encoder. the PCI-7344 can control up to four axes. Right-click on PCI Device and select Uninstall. . Lai Wechat:17750010683 Whats app:+86 17750010683The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. I met a problem in using the Labview and it is extremely urgent (I have to make it work in 24hrs). If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. PCI-7344 PXI-7344 PCI-7352 PXI-7352 PCI-7354 PXI-7354 PCI-7356. We updated our computer and now my actuators will not move. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. item 5 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 National Instruments NI PCI-7340 / PCI-7344 Motion Controller Card, 186307C-04 $500. 问题:. NI-Motion Issue Details I can command my motion controller to move a stepper motor to a target position in Open Loop mode, but when I configure it to run in Closed Loop mode, the motor doesn't appear to complete the move, doesn't move at all,. Hope this helps, Jorge M. 我用的松下的伺服电机和松下的伺服驱动,原来我用plc控制实现单轴移动,现在我想用umi- 7764和pci-7344 实现对电机控制. On the other hand please take into account that the PID loop is running much faster and in order to align the trajectory generation rate ( = 10 ms in contoured mode) and the PID rate (= up to 62,5 µs) the DSP. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. 0 and earlier. The PCI‑7334 offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high-performance stepper generation for ensuring smooth. Send documents to the printer connected to your host computer or to the printer connected to the computer you are. g. Please call or email us with your request. Due to a large instal. vi twice for both the Hardware and Software limits. Configure your stepper settings. If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. Re: PCI-7344 motor interfacing help. A much better choice is the use of a motion control board, e. Unfortunately the output pulse has a length of about 20 ms and so I have to decrease the speed of my stage rapidly (otherwise the. 5,控制方式采用的是位置控制模式. Bgrain, there is no way to tweak a PCI-7344. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. flx) to trigger a move (Start Motion. Shipping and handling. When I command an axis to move, there. I am looking at building a PXI Express chassis setup. A few month ago, i tried the same, but i lost the code and the motor moves so that the analog signal goes to 0V. Depending on the movement of a xy - stage (controlled by the motion controller) I'd like to trigger a laser pulse. Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms PID loop update rate, the National Instruments PCI-7344 (Part number: 778916-04) is a high-quality Motion Controller for stepper/servo control applications. vi and Read Limit Status. Select the Servo radio button. Please refer to the contouring examples shipping with LabVIEW. Allen C. (NI). 付属されていた新しいドライバCDはインストールしましたでしょうか?. I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver.